F75 boiler error code: what it means and what to do
Updated on 19th November 2026:
Joanna Flowers
Technical Repair Engineer, British Gas
If you’re seeing the F75 fault code on your boiler, it means it hasn’t detected the normal change in water pressure when the pump starts. As a safety precaution, your boiler will shut down until the problem is fixed.
Need help? Try our Instant Expert
Instant Expert is the online tool that gives you step-by-step instructions for simple boiler fixes. It’s quick, easy – and 100% free.
Which boilers use the F75 error code?
The F75 fault code is used on a number of Vaillant boilers, particularly in the ecoTEC plus, ecoTEC pro and ecoTEC exclusive ranges. It's also found on some Glow-worm boilers, including the Ultracom and Energy ranges.
What does error code F75 mean?
F75 usually appears when the boiler starts its pump but doesn’t detect the expected increase in water pressure. The boiler can’t confirm that water is circulating properly, so it displays the fault code and will usually stop working.
What are the signs of an F75 error code?
If your boiler shows F75, it may stop working and leave you without heating or hot water. You might also notice low system pressure and unusual noises from the pump.
What can cause the F75 error code?
F75 can be caused by a blocked or faulty water-pressure sensor, a failing circulation pump, low system pressure, trapped air, or sludge in the system stopping water circulating properly. Problems with the expansion vessel or electrical connections can also cause the F75 fault.
Can I fix the F75 boiler fault myself?
The F75 fault code is usually caused by problems that should only be tackled by an engineer, but there are a few simple things you can try before booking a professional.
- Check the boiler pressure. Low system pressure or insufficient water can cause F75. If your boiler pressure is below 1 bar, repressurise it following the instructions in your boiler’s manual.
- Try one reset. After checking the pressure, reset the boiler to see if the fault code clears and the boiler starts working properly.
When should I call an engineer for an F75 boiler error code?
If F75 is still displayed after you've checked the boiler pressure and done a reset, contact a Gas Safe registered engineer.
There may be a problem with the circulation pump, water-pressure sensor or heating system that needs an expert to repair.
How would an engineer fix an F75 boiler error code?
An engineer will check the boiler's water-pressure sensor and circulation pump, as well as the system pressure and any circulation problems. They'll also check the expansion vessel and electrical connections if necessary.
Depending on the cause, they may clean or replace the pressure sensor, repair or replace the pump, or fix the underlying pressure or circulation problem. They'll then test the boiler to make sure everything is working properly.
How can you prevent an F75 boiler error code in the future?
You can't always prevent an F75 fault, but regular servicing can help reduce the risk. We always recommend an annual boiler service to make sure everything is working safely and efficiently.
Still stuck? Try our online Instant Expert
Our Instant Expert tool is here to help. Just share some details about the issue and we’ll explain some simple things you can try to fix it yourself. It’s quick, easy and completely free.